Elgar GUPS Series (2400A, 2400U & 2400AD) : Specifications

Output

Output Voltage GUPS 2400A and 2400AD: 115 VAC ±2% over full range of line and load variations

Output Voltage GUPS 2400U: 115 VAC or 230 VAC ±2% over full range of line and load

Output Frequency GUPS 2400A: 60 Hz ±0.1%

Output Frequency GUPS 2400U: 50 Hz or 60 Hz ±0.1%

Efficiency: 70% from AC input, 65% from DC input (GUPS 2400AD only)

Output Current: 21 ARMS, 63A peak

Output Distortion: 2% maximum THD with linear loads

Output Power: 2400 VA into ±0.8 PF load

Output Overload: 150% for 30s; 150% to 200% for 3s. For GUPS 2400AD, when operating from DC input, overload capability is limited by 220A DC input current limit.

AC to DC Crossover: If AC input falls below or rises above the currently selected input range limits, the unit switches to battery. Unit switches to DC, if available, before switching to battery (GUPS 2400AD only).

The GUPS 2400A-104 variant providing a three phase input from 159-232 VAC line to line at frequencies from 370-430 Hz is also available. Contact Elgar for details on this model.

Power Loss During Crossover: None

New Expanded AC Product Line Featuring California Instruments
   
AC Electronic Loads
AC Modular Supply
Discontinued Products
Product Support
Contact Sales

Input


Input Voltage, AC: 85 to 140 VAC or 170 to 280 VAC
Single Phase

Input Current, AC: 33A at 120 VAC, 17A at 240 VAC

Input Frequency, AC: 45 to 450 Hz

Input Voltage, DC (GUPS 2400AD only): 20 to 32 VDC

Internal Battery Module: 192 VDC, 2.5 AH. Optional external battery packs available

Battery Hold-Up Time: 5 minutes for internal module with
2400 VA load, 0.8 PF @ 25°C. Adding one external battery pack increases time to a minimum of 18 minutes at full rated load. Reduced loads increase backup time.

Input Current DC (GUPS 2400AD only): 105A at 28 VDC

GUPS 2400AD: 10 minutes for external battery chassis with 2400 VA load, 0.8 PF at 25°C. Adding additional external battery packs increases backup time.


Environmental


Altitude: Operating 0 to 10,000 ft; non-operating 0 to 40,000 ft

Temperature: Operating 0° to 40°C; non-operating -40° to 65°C

Humidity: 5 to 95% non-condensing


General


Weight GUPS 2400A: 78 lbs, maximum without battery module. Removable internal battery module is 48 lbs (126 lbs max combined weight). GUPS 2400A-104 variant (123 lbs max combined weight).

Weight GUPS 2400U: 83 lbs, maximum without battery module. Removable internal battery module is 48 lbs (131 lbs max combined weight).

Weight GUPS 2400AD: Main chassis is 95 lbs; battery chassis 116 lbs, total weight 211 lbs.

Dimensions: 7"H x 19"W x 21"L (GUPS 2400AD two chassis)
7"H x 19"W x 25.1"L (GUPS 2400A-104)


Internal Battery Module


Battery Description (GUPS 2400A and GUPS 2400U): 192 VDC, 2.5 AH sealed lead acid

Configuration: 96 cells at 2.0 V, 2.5 AH in a single pullout, removable module

Recharge Time: 4 hours, 90% full charge with integral battery charger

Typical Minimum Hold-Up Time 2400 VA at 25°C: 5 minutes

Microprocessor Controlled Equalization: Batteries maintained on a temperature compensated, constant voltage float charge with automatic equalization as required

Temperature: Operating 0° to 40°C; non-operating -40° to 65°C

Weight of Removable Module: 48 lbs


External Battery Chassis for GUPS 2400AD


Battery Description:
192 VDC, 5 AH sealed lead acid

Configuration:
Two modules, 2.5 AH each

Recharge Time:
6 hours, 90% full charge with integral battery charger

Typical Minimum Hold-Up Time 2400 VA at 25°C:
10 minutes

Temperature:
Operating 0° to 40°C, non-operating -40° to 65°C


Alarms and Signals


Alarms:
The audible alarm sounds for an overtemperature, loss of AC input or improper battery voltage.

Signals:
(1) Isolated relay contacts signal loss of AC input and impending inverter shutdown due to low battery capacity and
(2) RS 232 data communications for computer interface provides information on GUPS status, alarms and parameter values.


Indicators


AC Input: A three color LED indicates the condition of the AC input voltage. The LED is green when the AC input voltage is within the normal operating limits, amber when the voltage is close to the limits of the operating range and red when the operating voltage range is exceeded.

Battery:
A three color LED indicates the condition of the battery. The LED is green under normal operating conditions, amber when the battery is discharging or has low capacity and red when impending inverter shutdown is approached.

Load:
A three color LED indicates the amount of output load.
The LED is green when the load is less than 80% of maximum output, amber when the load is within 80% to 105% and red when the load exceeds 105%, indicating that the inverter will shut down if the load is maintained.

Temperature:
A two color LED indicates the overtemperature condition of the GUPS.
The LED is green under normal operating conditions and red when an over- temperature occurs.

Test:
A two color LED indicates the results of the internal self-test. A blinking light indicates the test is in progress.
When the test is complete, the LED turns green if the GUPS passes the test and red if it fails.


Controls


Output On:
Switches on or off the GUPS output

Test:
Initiates the internal self-test

Alarm Silence:
Silences the audible alarm

Remote Shutdown (GUPS 2400U only):
Switches off the UPS output and disconnects the UPS from the AC input source.
Requires external SPST contact closure


Frequency Switch


Output Frequency (GUPS 2400U only): Selects 50 or 60 Hz output


Configuration Terminal Block


Output Voltage (GUPS 2400U only): Selects 115 VAC or 230 output